Wilbur Curtis TCT with Sweet Tea Option User Manual
Page 4

4
Tea Half Batch (Factory set to OFF).
Press to Select. Press < or > to toggle between OFF and ON. When ON, Half Batch Brew Button is activated.
Sweetener Time (Factory set to 48 Seconds)
Press to Select. Press < or > to toggle between minutes, seconds or exit. Pressing select to choose minutes will
increase the minutes. Press to add minutes. Press < or > to move to seconds or exit.
Temperature (Factory set to Standard Gray & Purple 204ºF)
Press to Select. Press < or > to choose Standard Gray and Purple 204ºF and then to set. Tropical Gray and Purple
and 76/308 Gray & Purple 196ºF are the other selections. Temperature range, from 170ºF to 208ºF in 2-degree incre-
ments.
Energy Save Mode (Factory set to OFF)
Press to Select, < or > ON, OFF or ON 140ºF , to set. When in ON, unit will automatically shut off 4 hours from
last brew. When feature is OFF, unit does not have the energy saving mode. In the ON 140ºF position, temperature goes
down to 140ºF. if unit has not brewed in 4 hours. This saves energy by lowering the tank temperature during periods of
non-operation.
Brew Count Odom.
Press to display total brew cycles. Press ex or Reset Brew Count Total. Press to Select, Shows total gallons and
total brew cycles on the unit. Resettable.
Brew Count Total
Press to Select, Shows total gallons and total brew cycles on the unit. Not resettable.
Cold Brew Lock (Factory set to 5º F)
Press to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The
first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for
the Ready to Brew message, however it will brew at any temperature.
Master Reset
Press to display Are You Sure? Then < for Yes, > for No. When Master Reset is used, the all of the menu selections
in the UCM return to factory defaults.
Service Call (Phone number Factory set to [800] 000-0000x)
Press to display number and change number or < to move place and EX to exit when complete. This number will be
displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4)
Press to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit.
Banner Name (Factory set to CURTIS)
Press to display letters and change letters or < to move place and EX to exit. This feature allows up to 14 letters to be
programmed for company name. Programming all blanks disables Banner Name. Banner Name is displayed 5 sec. on
and off.
P-Maintenance (Factory set to OFF)
Press to Select, Set gallons brewed to indicate P-Maintenance. Press < or > to adjust from Off to 3000 gal. Press
to exit.
Beeper On/Off (Factory set to ON)
Press to display ON or OFF. Pressing either < or > toggles between on and off. to set. When ON, the unit will emit a
short beep each time a button is pressed.
Temperature
Energy Save Mode
Brew Count Odom
Master Reset
Service Call
Brew Count Total
Cold Brew Lock
Access Code
P-Maintenance
Beeper On/Off
Banner Name
Tea Half Batch
Sweetener Time
PROGRAM MENUS CONTINUED
Continued on Page 5