beautypg.com

Wilbur Curtis D500GT User Manual

Page 4

background image

4

P-Maintenance

Beeper On/Off

Pulse Brew

On/Off

Access Code (Factory set to 1-2-3-4)

Press  to display number and change number, (the number can be change 1 to 4) or < to move place and ex to exit when complete.

Banner Name (Factory set to Curtis)

Press  to display letters and change letters or < to move place and EX to exit when complete.

This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks disables Banner

Name. If programmed, Banner Name is displayed every 5 sec. on and off.

P-Maintenance (Factory set to OFF)

Press  to Select, Set gallons brewed to indicate P-Maintenance. Press < > to adjust from Off to 3000 gallons. Press  to exit.

Beeper On/Off (Factory set to ON)

Press  to display ON or OFF. Pressing either < > toggles between on and off. Press  to set.

Pulse Brew (Factory set to OFF)

Press  to select. Display will now show Select Button. Select desired Brew button to program. The next screen will promt you to

press < > to select OFF or one of five pulse patterns (A to E) .

Guidelines for Pulse Brew:

This feature allows tuning of the coffee flavor. The pot level should always be set first with this option OFF. Depending on your grind

profile and water conditions, the five Pulse Brew options help “tune” or change the coffee flavor. Filter Pack type coffees typically

extract better with the A and B pulse setting. Decaffienated coffees typically extract better with the B pulse setting. High-Yield coffees

typically extract better with the C pulse setting. Of course, any of the A, B or C settings may be used to suit your taste profile. There are

two additional settings (D and E) that alow you to manually set the ON TIME pulses and OFF TIME.

If Pulse Brew is selected (ON), Cold Brew Lock is set to within 5ºF of set point. Also, the Cold Brew Lock and Pre-infusion

features disappear from the list of program selections.

Display Brew Time (Factory set to ON)

Press  to display ON or OFF. Pressing either < or > toggles between on and off.  to set. When on, the Display Brew Time feature

allows you to see the remaining time in the brewcyle counting down.

Drip-Out Mode (Factory set to 2 min)

Press  to select. Press > to increase time (to a maximum of 5 minutes) or < to decrease the time and turn OFF. Time counts up in 5

second increments. Press  to set.
Display Messages (Factory set to ON)

Press  to turn ON or OFF. The message displayed is “Rinse Server Before Brewing”. This message will alternate; two seconds with

Rinse Server Before Brewing, then Curtis READY TO BREW will appear for six seconds..

Language (Factory set to English)

Pressing < or > toggles between English and French. Press  to set.

Model Select

Press  to select, < or >. Be sure that Airpot Brewer is selected. Screen choices are: ALPHA-1, ALPHA-2, ALPHA-3/4/5, Airpot Brewer

and Thermo-Alpha. Press  to set. All menu settings will default to factory standards whenever a new model is selected.

Exit

Press  to select, exits program mode and returns unit to operation. Pressing > returns you to Brew By Volume.

Banner Name

Access Code

Exit

Model Select

Display Brew

Time

Drip-Out Mode

Display Messages

Language