MAINTENANCE

WARNING:

To avoid serious personal injury, always remove the
batteries from the tool when cleaning or performing any
maintenance.

GENERAL MAINTENANCE

n

Before initial use, wipe AIRgrip vacuum base with a damp

cloth to remove any residue.

n

Store the unit indoors.

n

When not in use, the vacuum base and attachments

should be kept in the protective case.

n

Keep the unit free of dust and liquids. Use a damp cloth

and mild soap to clean the outside casing. Avoid using
solvents when cleaning plastic parts. Most plastics are
susceptible to damage from various types of commercial
solvents and may be damaged by their use.

�n To clean the laser lens, if needed, use ONLY a soft cloth

or cotton swab moistened with glass cleaner.

n

Check the batteries regularly to avoid deterioration. Re-

move the batteries from the vacuum base if you will not
be using them for an extended time.

�n Do not disassemble the laser level. This could cause

exposure to hazardous laser radiation.

n

Do not attempt to change any part of the laser lens.

WARNING:

Do not at any time let brake fluids, gasoline, petroleum-
based products, penetrating oils, etc., come in contact
with plastic parts. Chemicals can damage, weaken, or
destroy plastic, which may result in serious personal
injury.

ALWAYS BE AWARE of the location
where the laser light is emitted when
using the laser level attachment. AL-
WAYS MAKE SURE that any bystanders
in the vicinity of use are made aware of
the dangers of looking directly into the
laser beam.

TROUBLESHOOTING

Problem

Possible Cause

Solution

Vacuum not running

Batteries are low
Power is turned off

Replace batteries.
Press on/off button.

Laser line projection is weak

Batteries are low

Replace batteries.

Laser line is hard to see

Light in area is too bright

Dim light in the work area or use laser-
enhancing glasses.

Light is not working

Power is not “on”
Batteries are low

Press the on/off button.
Replace batteries.

Light is dim

Batteries are low

Replace batteries.

Vacuum base won’t stick to wall

Surface is incompatible for vacuum

Use rough-surface adaptor on stucco
and textured surfaces.