Maintenance Instructions

1. Vibrator Lubricaton

The vibrators are lubricated as supplied. The lubrication is good for 2,000 to

5,000 hours. SEE MANUFACTURING INSTRUCTIONS.

2. Isolators

Because of the various size Live Bins and the varying density of products
being handled, we use three (3) styles of isolators:

1) Solid Rubber Mounts

These require no maintenance, only periodic checking for damage due to
aging, chemical attach, or severe overloading.

2) Air Mounts

These require periodic checking for loss of pressure. If re-pressurization
is required, standard tire filling equipment can be used to fill mount to the

proper pressure.

3) Liquid Filled Air Mounts

These are air mounts that are filled with a mixture of water and

antifreeze. They are pressurized to a design height of 5 _ to 6 _ inches.
If pressure is lost, they can be filled using an air hose and fittings fitted to

a water tap.