SECTION II: SPECIFICATIONS

Table 1.

Specifications

.

Model

TGHE-160E-N(X) TGHE-199E-N(X)

Minimum Rate Btu/h

9,500 (Natural) / 10,300 (Propane)

Maximum Rate Btu/h

157,000

199,000

Flow Rate (Min-Max) *

0.4-8.0 GPM (1.5-30 L/min)

0.4-9.8 GPM (1.5-37 L/min)

Flow Rate (45°F rise)

6.6 GPM (25 L/min)

8.5 GPM (32 L/min)

Default Temperature Setting

104°F (40°C)

Maximum Temp Setting (commercial
**)

185°F (85°C)

Maximum Temp Setting (residential)

Selectable at 120°F (49°C) or 140°F (60°C)

Minimum Temperature Setting

98°F (37°C)

Weight

64 lb (29 kg)

71 lb (32.2 kg)

Energy Factor

0.96

0.94

Thermal Efficiency

95%

Noise level (inside rating)

50 dB

Electrical

Consumption

Normal

44 W

59 W

Standby 2

W

Anti-frost Protection

172 W

172 W

By-Pass Control

Electronic

Minimum Gas

Supply

Pressure

Natural Gas

5.0 inch W.C.

Propane

8.0 inch W.C.

Maximum Gas

Supply

Pressure

Natural Gas

10.5 inch W.C.

Propane

13.5 inch W.C.

Type of Appliance

Condensing, Tankless, Direct Vent, Temperature controlled continuous flow gas

water heater

Operation

With or without remote controls, mounted in kitchen, bathroom, etc.

Approved Gas Type

Natural Gas or Propane - ensure unit matches gas type supplied at the installation

location.

Connections

Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4"

MNPT

Ignition System

Direct Spark Ignition

Electric Connections

Water Heater: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)

Water Temperature Control

Simulation Feedforward and Feedback

Minimum Water Supply Pressure

50 PSI (Recommended 60-80 PSI for maximum performance)

Maximum Water Supply Pressure

150 PSI

Remote Control Cable

Non-Polarized Two Core Cable (Minimum 22 AWG)

ENERGY STAR

®

Qualified

Yes


* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.

** For commercial and hydronic applications requiring higher temperatures. Requires the use of an optional controller
(P/N 239-48789-00).

Bradford White Corporation is continually updating and improving products. Therefore, specifications are subject to
change without prior notice.

The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value
listed is for the purpose of input adjustment.

This manual is related to the following products: