Troubleshooting – Electrical

There are a number of (live) tests that are required when fault finding this product. Extreme care should
be used at all times to avoid contact with energized components inside the water heater. Only trained
and qualified service technicians should attempt to repair this product. Before checking for resistance
readings, disconnect the power source to the unit and isolate the item from the circuit (unplug it).

Table 11.

(SV1, SV2, SV3, SV4, and POV) Gas Valve and Modulating Solenoids (Set Meter Above 2k).

Wire Color

Voltage

Resistance

Connector

No.

Pin

Nos.

(SV0) Pink-Black

11-13 VDC

37-43 ohms

B5

7-8

(SV1) Blue-Black

11-13 VDC

37-43 ohms

B6

6-7

(SV2) Yellow-Black

11-13 VDC

37-43 ohms

B7

5-7

(SV3) Red-Black

11-13 VDC

37-43 ohms

B3

4-7

(SV4) Orange-Black

11-13 VDC

37-43 ohms

B4

3-7

(POV) Orange-Orange

2-15 VDC

67-81 ohms

B2

10-11

Table 12.

(M) Water Flow Control Device Servo.

Wire Color

Voltage

Resistance

Connector

No.

Pin

Nos.

Red or Pink-Orange

5-7 VDC

n/a

G2

3 or 4-

8

Blue or White-

Orange

5-7 VDC

n/a

G2

1 or 2-

8

Red-Pink n/a

30-50

ohms

G2

3-4

Blue-White n/a 30-50

ohms G2

1-2

Gray-Yellow 0-6

VDC

n/a

G2 7-5

Gray-Brown 0-6

VDC

n/a

G2 7-6

Note: The grey wire listed above turns to black at F connector on the PCB.

Table 13.

(QS) Water Flow Sensor.

Wire Color

Voltage

Resistance

Connector

No.

Pin

Nos.

Black-Red 11-13

VDC

n/a

E5 1-3

Yellow-Black

4-7 VDC

1-1.4 Mega ohms

E5

2-3

Table 14.

By-pass Flow Control.

Wire Color

Voltage

Resistance

Connector

No.

Pin

Nos.

Brown-White

2-6 VDC (unit

in operating

mode)

15-35 ohms

G1 1-5

Orange-White G1

2-5

Yellow-White G1

3-5

Red-White -

Ground

G1 4-5

Table 15.

(IG) Ignition System.

Wire Color

Voltage

Resistance

Connector

No.

Pin

Nos.

Grey-Grey 90-110

VAC

n/a

D1 1-2