Step 5. Fully inspect burner door and right side inner door gaskets for the following:

>Tears

>Other imperfections that will inhibit proper seal

>Missing Material

>Gasket adhesion to inner door

>Cracks

>Material left on combustion chamber (around opening)

>Dirt or debris

If the gasket is not effected by any of the above, gasket replacement is not required. If replacement is
required, proceed to Inner Door Gasket Replacement Procedure.

Inner Door Removal Procedure
Step 1.

Rotate the gas control knob to the “OFF”

position.

Step 2.

Remove outer jacket burner access door.

Step 3.

Remove wire clip from main burner feedline.

Step 4.

Inner Door Removal.

a) Disconnect red thermopile lead and red gas control lead from

resettable thermal switch. Disconnect white thermopile lead
from the gas valve (see photos 1 and 2).

b) Disconnect main burner feed line (¾” wrench), pilot tube

(7/16" wrench) and igniter wire from gas control (see photo 2).

c) Remove (2) ¼” hex drive screws from right side inner door

(see photo 3).

d) Remove (2) ¼” hex drive screws from flange section of

inner door (see photo 3).

e) Remove (3) 1/4" hex drive screws from burner door

(see photos 4&5). The burner door and burner are

one-piece.

f) Remove burner and inner door and inspect per step 5.

ECO-MAGNUM

75/100-Gallon Atmospheric

SERVICE PROCEDURE I

Burner and Inner Door/Gasket Removal,

Inspection, Replacement and

Reinstallation

Gas Control Knob Shown In

“OFF” Position

1

2

3

4

5

Red Thermopile Lead

Red Gas

Control Lead

White Thermopile

Lead

Main Burner

Feedline

Pilot Tube

Igniter Wire

Right Side

Hex Drive

Screws

Flange Hex

Drive

Screws

Burner Door

Hex Drive

Screws

Position #1

Position #2

Position #3

7