beautypg.com

Eco-magnum – Bradford White U-100T-88R-3N User Manual

Page 20

background image

SERVICE PROCEDURE VIII

Dip Tube and Anode

Inspection and Replacement

Step 1.

Rotate gas control knob to the “OFF” position.

Step 2.

Turn off cold water supply to water heater. Connect hose to drain valve of water heater and route to an open
drain. Open a nearby hot water faucet to vent heater for draining. Open drain valve of water heater and
allow water heater to drain to a point below the inlet connection nipple.

Step 3.

Disconnect inlet nipple from plumbing system.

Step 4

With an appropriate wrench, remove inlet nipple/dip tube from the water heater. Use caution not to damage
pipe threads.

Step 5.

Visually Inspect inlet nipple/dip tube. Inlet nipple/dip tube should be free of cracks and any blockage.
Hydro-jets located near the bottom of the dip tube should be open and free of any blockage.
Anti-siphon hole located approximately 6" from the bottom of nipple, should be free of any blockage.

Any damage such as cracks, restriction due to deformation or unintentional holes are not field repairable
and the inlet nipple/dip tube must be replaced.

Step 6.

Upon completion of inspection or subsequent replacement, reinstall inlet nipple/dip tube into heater. Connect
nipple to plumbing system, resume water supply and refill water heater with water.

Step 7.

To resume operation follow the instructions located on the lighting instructions label or the lighting
instructions located in the installation and operation manual.

Dip Tube Inspection and Replacement

WARNING

Water Heater components and stored water may be HOT when performing the following

steps in this procedure. Take necessary precaution to prevent personal injury.

Gas Control shown in the “OFF” position

Page 20

ECO-MAGNUM

75/100-Gallon Atmospheric

20