Gas Control & Thermal Well Removal From Water Heater
Note: The Component Disassembly, Gas Control Removal, and Gas Control Assembly
sections replace pages 24-30 in the Defender Atmospheric service manual, p/n
238-44943-00.

Step 1.

Move the gas control power switch to the “OFF”

position.

Step 2.

Unplug the water heater and Accessory Module from the

wall outlet.

Step 3.

Drain the water heater to a point below the gas control

level.
Step 4.

Turn off the gas supply to the water heater and disconnect

the gas piping from the gas control.
Step 4.

Disconnect the pilot tube

using a 7/16” wrench and the main burner
feedline with a 3/4” wrench from the gas
control.

Step 5.

Disconnect the wire harnesses and spark igniter/

flame sense wire from the gas control.

Step 6.

Remove the gas control & thermal well by rotating

the flats of the Thermal Well counter clockwise using a 1-5/16”
wrench.

Component Disassembly

Gas control power

switch

Pilot and main

feedlines

Spark igniter/flame

sensor wire

Gas control

Flats of thermal

well

Water heater power cord and

Accessory Module transformer