beautypg.com

Pilot maintenance – Bradford White PE-2-XR504T6FSX User Manual

Page 20

background image

Page 20

Pilot Inspection, Testing, and Replacement (cont’d)
Step 6.

Disconnect the pilot tube

using a 7/16” wrench and the main burner
feedline with a 3/4” wrench from the gas
control.

Step 7.

Disconnect the spark igniter/flame sensor wire from

gas control.

Step 8.

Remove the burner assembly from the combustion

chamber.

Step 9.

Remove the pilot assembly from the main feedline

using a 1/4" nut driver.

Step 10.

Visually inspect the spark igniter/flame sense wire for damage. Replace

the pilot assembly, if damage is found.

Step 11.

With a multi-meter set to the ohms setting, check

continuity through the spark igniter/flame sense wire. Replace
the pilot, if there is no continuity.

Pilot Maintenance

Pilot and main

feedlines

Spark igniter/flame

sensor wire

Gas control

Burner assembly

Pilot assembly

1/4” nut driver

Multi-meter

20