SERVICE PROCEDURE RG-VI

Gas Control

Testing, Disassembly & Replacement (Honeywell)

The Bradford White

DEFENDER

Safety System

®

GAS CONTROL REPLACEMENT

Step 1. Rotate knob of the Gas Control to the “OFF” position.

Step 2. Turn off gas supply to water heater.

Step 3. Disconnect gas supply line from Gas Control.

Step 4. Turn off water supply and drain water heater completely.

Step 5. Remove outer jacket burner access door.

Step 6. Right side inner door removal.

a) Disconnect red wire leads from resettable thermal switch.

b) Remove (2) hex drive screws from RIGHT side inner door.

c) Remove (2) hex drive screws from FLANGE SECTION of inner door.

d) Remove right side inner door and set aside. Be careful not to damage gasket material on inner door.

Rotate knob counter-clockwise
to the “OFF” position.

Resettable Thermal Switch

Wire Connection

Hex Drive Screws

Right and Left Side Inner Door.

Hex Drive Screws at

Flange Area of Inner Door

Remove
Wire Tie

Step 7. Removal of Gas Control.

a) Disconnect main burner feedline, pilot tube, piezo igniter wire, inner door wire (red) and thermopile wire

(white) from Gas Control.

b) Remove Gas Control from water heater by rotating counter clockwise. DO NOT use a wrench on the

Gas Control body, damage to the Gas Control may occur. If necessary, use a length of ½" NPT pipe

threaded into gas inlet of Gas Control.

Step 8. Install new Gas Control into water heater.

a) Install new Gas Control into water heater by rotating clockwise. DO NOT use a wrench on the Gas

Control body, damage to the Gas Control may occur. If necessary, use a length of ½" NPT pipe threaded

into gas inlet of Gas Control.