B&C Technologies DI-475 Industrial User Manual
Page 38

(
SECTION 7
TROUBLESHOOTING
IMPORTANT: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and
THE GAS SUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS or GUARDS ARE
REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING,
INSTALLATION, or TESTING OF ANY EQUIPMENT per OSHA
( Occupational Safety and Health Administration ) STANDARDS.
The information provided will help isolate the most probable component (s) associated
With the difficulty described. The experienced technician realizes, however, that a Loose
connection or broken/shorted wire may be at fault where electrical components
are concerned…not necessarily the suspected component itself. Electrical parts should
always
be checked for failure before being returned to the factory.
IMPORTANT:
When replacing blown fuses, the replacement
must be
of the exact rating as
the
fuse being replaced. The information provided
should not
be misconstrued as
a handbook for use by an untrained person in making repairs
WARNING: ALL
SERVICE AND TROUBLESHOOTING
SHOULD BE
PERFORMED
BY A QUALIFIED PROFESSIONALOR SERVICE AGENCY.
WARNING:
WHILE MAKING REPAIRS, OBSERVE
ALL
SAFETY PRECAUTIONS
DISPLAYED ON THE DRYER OR SPECIFIED IN THIS MANUAL
A. No display…
1. Service panel fuses blown or tripped breaker
2. Blown
FU1
fuse 1 or
FU2
fuse 2
3. Failed microprocessor controller (computer)
B. Drive motor not operating (does not start)…
* Microprocessor controller (computer) relay output indicator (either) forward
“FWD” or reverse “REV” is on
1. Blown drive motor contactor fuse (s)
2. Failed drive motor contactor
3. Failed drive motor
4. Failed soft start
* Microprocessor controller (computer) relay output indicator (neither) forward
“FWD” or reverse “REV” go on