Installation – B&C Technologies HP Series Commercial User Manual
Page 24
Installation
Electrical Installation
23
Machine
Max Amps Breaker
Wire Size
Max Amps Breaker
Wire Size
HP-60, 3PH
8
15
14ga / 2.5mm
4
15
14ga / 2.5mm
HP-60, 1PH
13.6
15
14ga / 2.5mm
200-240V
380-480V
Note: For single phase (1N) operation,
connect input power to L1 and L2, leaving
the L3 terminal open.
Note: Do not use phase adders (roto-phase)
on inverter driven equipment!
Note: Wire sizes shown are for copper,
THHN, 90 conductor per NEC article 310
(USA).
The machine should be connected to an
individual branch circuit not shared with
lighting or other equipment.
Because this is a vibrating machine, the use
of SO cable or similar, with a twist-lock
plug, to connect the machine to main power
is recommended. A shielded liquid tight or
approved flexible conduit with proper
conductor of correct size installed in
accordance with National Electric Code
(USA) or other applicable codes is also
acceptable. The connection must be made
by a qualified electrician using the wiring
diagram provided with the machine. See
the Electrical Connection data Chart for
correct wire sizes.
Use wire sizes indicated in the chart for runs
up to 50 feet (15m). Use next larger size for
runs of 50 to 100 feet (15-30m). Use 2 sizes
larger for runs greater than 100 feet (30m).
For personal safety and for proper
operation, the machine must be grounded
in accordance with state and local codes
and in the USA in accordance with the
National Electric Code, article 250-96.
The ground connection must be to a proven
earth ground, not to conduit or water pipes.
Do not connect the ground to the neutral
(N) leg at the terminal strip (if so equipped).
If a DELTA supply system is used, the high
leg should be connected to L3, since
control voltage is derived from L1 and L2.
Insure that the control transformer taps are
connected in accordance with the incoming
line voltage. Verify connections as shown
on the schematic with each machine.