When installing the washer-extractor, it is
important to allow adequate clearance on
all sides of the machine. When multiple
machines are installed, it is important to
allow for the specified minimum clearances
between machines. The following table
shows recommended minimum clearances
for the various freestanding models.
Note
The dimensions are approximate and
subject to normal manufacturing tolerances.
If exact dimensions are required for
construction purposes, request certified
drawings from the factory. We reserve the
right to make changes at any time without
notice.
16
Installation
Dimensional Clearances
A
B
C
D
UNITS
UNITS
Metric
US
(A) Minimum rear clearance
mm
in
760
30
305
12
(B) Minimum clearance between
machine and wall
mm
in
455
18
25
1
(C) Minimum clearance between
machines
mm
in
455
18
25
1
(D) Minimum front clearance
mm
in
838
33
838
33
HP Series