Regular Checks
Routine Use
During use, check the following regularly:
Once a month check the balance of the camera and
payload and adjust if necessary.
Check the integrity of bolts and fixings securing the head to
the support.
Check the bolts and fixings securing the payload.
No further routine maintenance is required.
Ÿ
Ÿ
Ÿ
Cleaning
We encourage regular cleaning of the product. During normal
use the only cleaning required should be a regular wipe over
with a lint-free cloth. External electrical connection ports should
only be cleaned with a vacuum cleaner.
Cover the head when not in use. Dirt accumulated during
storage or periods of non-use may be removed with a vacuum
cleaner.
Changing the Fuse
WARNING! Risk of electric shock.
Disconnect the power cable. Fuses must only be
changed by a trained and competent person.
16
Maintenance
WARNING! Risk of electric shock.
Disconnect and isolate the product from the power
supply before cleaning.
1.
2.
3.
Switch OFF and disconnect the power.
Note: It is not necessary to remove the payload or cabling.
Using a flat-blade screwdriver or coin, remove the fuse
holder.
Replace the fuse, then reinstall the fuse holder.
Installation Guide
FH/FHR-145 Pan and Tilt Head
CAUTION! The replacement fuse must be the
correct rating: Type T3.15A, 250V AC.