Alarms

Alarm
Indicators*

The control panel has an audible buzzer and an alarm indicator light (Row 4)
that turns on when an alarm is triggered. In addition, the control panel will
flash the following codes when an alarm is triggered:

Alarm Code

What it means

What to do

P1, P3

Probe Failure

Call CellarPro at 877.726.8496

HA

The temperature inside
the cellar is too warm
(>70°F for more than 1
hour)

Check seals;

Check if door was left open;

Lower the ambient temperatures

HA2

The condenser
temperature is too high
(above 140°F for 2
hours)

Check for appropriate installation, ventilation,
ambient conditions and cooling capacity

Clean the condenser coils and/or replace the air
filter;

Check for obstructions to the intake and/or
exhaust vents;

Check that the condenser fan is operating

LA2

The temperature at the
condenser coils
(outside the cabinet)
has dropped below the
alarm temperature
setting

Lower the alarm temperature setting as follows:
1. Depress the “Set” and “Down” button for

three seconds until the controller displays a
parameter (eg “HY”), then release

2. Depress the “Set” and “Down” button again

for seven seconds until the “PR2” flashes on
the display, followed quickly by a parameter
(eg “HY”), then release

3. Using the “Down” button, scroll until the

display reads “AL2”

4. Depress the “Set” button
5. Use the “Down” button to lower the alarm

temperature setting to 45

6. Depress the “Set” button again
7. After three seconds, the display will return to

the normal screen

* Please note: the temperature alarms (HA, HA2, LA and LA2) are disabled during the first 23
hours of operation after the cooling unit is plugged in and/or turned on.