beautypg.com

Vintage Cellars LECBILD1800 User Manual

Page 21

background image

B I L D W I N E C A B I N E T S

-21-

Set Button

The cooling unit is factory preset with a Minimum
Set Point of 58°F and a Temperature Differential
of 4°F. This means that the cooling unit will turn
on when the display rises above 62°F (58°F +
4°F), and turn off when the display falls below
58°F.

To view the Minimum Set Point, press the “Set”
button for one second.

To change the Minimum Set Point:

1. Press the “Set” button for three seconds

until “°F” blinks

2. Press the “Up” or “Down” button
3. Press the “Set” button to confirm

The “Set” temperature will blink three times to
indicate confirmation.

The recommended Minimum Set Point range is
53 - 60°F. To change the Temperature
Differential, see “Advanced Operation” later in
this chapter.

Energy Saver Button

To activate and deactivate the “Energy Saver”
mode, press the “Energy Saver” button

The “Energy Saver” indicator light will turn on
when the cooling unit is in “Energy Saver” mode

In “Energy Saver” mode, the Minimum Set Point
increases 4°F and the Temperature Differential is
unchanged

Quick Chill Button

To activate the “Quick Chill” mode, press the
“Up” / “Quick Chill” button for three seconds.
To deactivate “Quick Chill”, press “Quick Chill”
button for three seconds again

The “Quick Chill” indicator light will turn on
when the unit is in “Quick Chill” mode.

In the “Quick Chill” mode, the unit will run
continuously for 6 hours (or until the intake
temperature registers 50°F). This mode is useful
after loading “warm” bottles in a cellar