Vetter safety cushion sp 16, Test regulation for annual inspection – Vetter SP 16 User Manual
Page 12
![background image](/manuals/641019/12/background.png)
VETTER Safety cushion SP 16
Page 11/15
Place the valve protection cap.
Fold over the packing tarpaulin. The safety cushion can now be
tightened with the belts. The belts can now be tightened to such
a degree as necessary. Tension the belts at the corresponding belt
tensioners according to requirements.
It must be ensured that air vent valves are closed and
that the safety cushion is packed together with a filled
compressed-air cylinder. The compressed-air cylinder
used for this purpose comes under pressure vessel direc-
tive. Please observe the recurring test periods!
The safety cushion is now ready for being stowed away in a ve-
hicle.
Test regulation for annual inspection
and check after each use
Manufacturing no:
Year of manufacture:
Test/check due:
1. Year
2. Year
3. Year
4. Year
6. Year
7. Year
9. Year
11. Year
12. Year
14. Year
To be scrapped after 15 years
The test and its results shall be recorded in writing by
filling in the test protocol,
9
an entry in the logbook for tests,
9
a note directly attached to the safety cushion (once a year
9
only).
Test regulation for the checks to be made without falling
loads after each use
1. Visual inspection of the cleaned safety cushion, in order to
identify external damage under inflated conditions.
1
2
3
4
6
7
9
11
12
14
15