beautypg.com

Repetitive checks – Vetter Lifting bags 1 bar (14.5 psi) User Manual

Page 13

background image

Page 12/15

6.

Repetitive checks

Repetitive checks are to be made on lifting bag systems as follows:

9

Testing

during

acceptance

Check to ensure that all items are present and complete; this

is made by the person commissioned for the task.

A visual and function test is to be made by an instructed per-

son according to the operating instructions.

9

A visual and function test is to be made after each period of

use / application and carried out by the user.

This test is to be documented.

9

The lifting bag system is to undergo a visual test and function

test at least once each year by a specialist (*) and is to be made

according to the check list (available on request).

This test is to be documented.

(*) Qualification see premilinary remarks on GUV G 9102

9

At least every 5 years, or if there is any doubt about the safety

or reliability, the lifting bag system is to be tested according

to GUV-G 9102 (formally GUV 67.13) by the manufacturer.

The responsibility for the correct and professional execution of