Vetter Lifting Bags 1.0 bar/14.5 psi

Page 9/15

Remember to remain at a safe distance from
the load! Do not stand directly in front of
the lifting bags because if the positioning
is incorrect the bags could be catapulted
outwards.

Never leave the controller and the inflation device unattended
while the lifting bags are under pressure. Never disconnect the
connection between bags and controller while the bags are under
pressure.

Additional information for illuminated control element
Air CU 1 bar Totmann lighting

The lighting of the control element illuminates all couplings,
switch levers and manometers. It is switched on and off with
Switch (1) on the side.
The control element is supplied by a 9 V block battery. Since the
entire lifting bag system is designed for a temperature range of
-20 °C to +55 °C, only batteries with this temperature range are
allowed to be used. Based on the current state of the art, only li-
thium batteries meet this requirement.
To insert the battery, unscrew the battery compartment, replace
the old battery with a new one and screw the battery compart-
ment back together.
Control elements with lighting come under the German Law on
electrical and electronic devices (ElektroG) of 24 March 2005 for
implementation of the EC Directive 2002/96/EC on electrical and
electronic waste – WEEE Directive.
The label attached to the battery compartment cover points
out that the electronic components in this product must not be
handled as domestic waste; they have to be returned to the ma-
nufacturer (return freight paid) for recycling.