Pressure test of mini lifting bags 8 bar / 116 psi

Note!

This test only applies to the pressure test required after 5 years, respec-
tively 10 years. This test is only to be carried out by a specialist having
additional training from the manufacturer or it is to be carried out by the
manufacturer himself!

Bag type

Serial no.

Year of manufacture

1. Visual inspection

If heavily soiled, first clean the bag with a lukewarm soap solution

Yes

No

1.1

The inflation connection is free of mechanical damage.

1.2

The surface of the bag, including the edge areas, are

free of punctures, cuts, tears or any other types of dama-

ge.

Remember! The execution of the 5 yearly test consists of an over-pressure test

and is mainly carried out with water pressure. The test pressure is 10.4 bar

(8 bar x 1.3) with mini lifting bags.

2. Pressure testing (water pressure test) – Remember: test time from 3 to a max.

of 5 minutes

Pre-fill the bag with the mains supply pressure to approxi-

mately 4 - 5 bar.

Ventilate a number of times using the test head.

Yes

No

2.1

Bag is free of atypical bulges on both sides.

Increase the internal bag pressure to the maximum pres-

sure of 10.4 bar using a hand pump

2.2

The bag is free of atypical bulges, tears, cuts or any

other forms of damage as well as having a nipple

connection which is perfectly sealed.

After termination of the test time of 3 to 5 minutes, carry out pressure

release via the test head and empty completely. Do not load the nipple

in any way when emptying and drying.

The bag is in perfect order

Bag is to be taken out of commission

permanently

Reason:

____________________ ____________________
Date

Signature/Tester