Subscriber timers – Ring Communications DXC910 User Manual
Page 22
22
DXC910 OPERATIONS MANUAL
2007/05/17
Call Number DA DD-0 DD-1 DD-2 DD-3 DD-4 DD-5 DD-6 DD-7 DD-8 DD-9
=========== ==== ==== ==== ==== ==== ==== ==== ==== ==== ==== ====
14 23
>
SUBSCRIBER TIMERS
There are 8 timers that can be set individually for each subscriber. A timer value of 0 means no time
limit.
PROGRAMMING
The following commands are used for this feature.
SST
Set Subscriber Timer
LST
List Subscriber Timers
Example: Set warning tone length (timer 2) to 1 sec. when subscriber 15 receives calls .
>SST
cr
Call Number <10-99/*> : 15
cr
Timer ID <1..8> : 2
cr
Timer Value <0....50> :10
cr
>LST
cr
Call Number <10-99/*> : 15
cr
Timer ID <1..8> : *
cr
Call Number ID Timer Setting Resolution Limit
=========== ======================= ======= ========== =====
14 1 Direct Dial (A) 12 0.1 sec 30
2 Warning Tone (B) 10 0.1 sec 50
3 Call Length (A) 1.0 sec 240
4 Group Call (A) 60 1.0 sec 600
5 All Call (A) 60 1.0 sec 600
6 PQUE Ring Delay (B) 2 1.0 sec 240
7 Camp on Privacy (A) 15 1.0 sec 240
8 Camp on Busy (A) 20 1.0 sec 240
>