Caller id, Device types – Ring Communications DXC910 User Manual
Page 18

18
DXC910 OPERATIONS MANUAL
2007/05/17
CALLER ID
Each subscriber in the system has 12 alphanumeric characters for identification. This ID is available for
display on the called station (DAD104) and for Event Logging (DNA100). Default is all spaces.
PROGRAMMING
The following commands are used for this feature:
SCID
Set Caller ID
LCN
List Call Number
Example: Set Caller ID for call number 14 to “Lobby”.
>SCID
cr
Call Number <10-99/*> : 14
cr
Caller ID
cr
>LCN
cr
Call Number <10-99/*> : 14
cr
Line Call In Priority
Equ. Number Caller ID Type QUE Alarm Call Annunciator Printer Video
==== ========= ========== ==== ==== ===== ==== =========== ======= =====
$04 14 Lobby ICM RING 1 5 ... ... ...
>
DEVICE TYPES
The device type defines the operation of intercom stations.
Type0 = Undefined
Type1 = SUB (DC shift substation)
Type2 = ICM (Master station or substation using speed-dial)
Type3 = PTT (Telephone line)
Type4 = TIE (Intersystem Tie-line)
PROGRAMMING
The following commands are used for this feature.
SDT
Set Device Type
LCN
List Call Number
>SDT
cr
Call Number <10-99/*> : 11-14
cr
Device Type(0=U 1=SUB 2=ICM 3=PTT 4=TIE)<0..4> : 1
cr