Ring Communications DNA934P User Manual
Page 14

DNA934P Telephone Dialer with Recorder February 2013
RM5000EX / CB901EX CONFIGURATION
The DNA934P consist of one station port and one annunciator port in the Central exchange.
The interface can be used to manually dial out on the telephone line from a master station by
dialing the extension of the DNA934P. A telephone can dial in to the central exchange by
dialing the phone number of the DNA934P then dial any intercom extension.
When the DNA934P receives a transfered call it will dial the telephone numbers that are
programmed in choices 1-4.
Example:
Adding the DNA934P to an existing system.
Connect voice to call number 30.
Connect date to RS485 using Network address 0C.
Calls are to transfer from intercom 10 to the DNA934P if not answered by intercom 10 within
30 seconds.
Programming commands that need to be added to RM5000EX:
EX500>
SDT 30 2 Set device type ICM
EX500>
SPT 30 11 + Set privilege “silent ring”
EX500>
SNA 30 1 0C Assign annunciator to call number 30
EX500>
STN 10 1 30 Set transfer from intercom 10 to 30
EX500>
STD 10 1 05 Set transfer delay (5x6=30 seconds)