Key beep on buzzer on, Back-light 50% cooling fan auto, Completion ring beep always – ProgressiveRC 3010B iCharger User Manual
Page 11: Discharge reduce off 50% delay 0min
-11-
iCharger Synchronous Balance Charger/Discharger 3010B
When Regenerative discharge is set to ON, discharging by charger internal consumption turns to charging
power supply (current and voltage limit can be set), which is shown in the following graph.
Note:
1. When in Regenerative discharging, charger‘s power supply needs to be
rechargeable
. For example,
Pb battery can be used for input power supply, but switch power adapter cannot.
2. The setting of regenerative discharge‘s current and voltage limit should be suit for power supply. For
example, using 12V Pb battery as power supply, the regenerative current and voltage should not be more
than its max charging current and voltage, or
it may cause danger
.
3. Regenerative discharge max power is the same with charger‘s setting max charging power, not
discharging power. (Restricted by setting regenerative discharge current and voltage limit, and discharge
current limit.)
4. Regenerative current limit is
not very accurate
, which may be 20% difference, max.
5. If input power supply voltage is more than setting regenerative limit voltage, charger will not start
regenerative discharge and internal discharge instead.
Key Beep ON
Buzzer ON
-
Dec
+
Inc
Inc
Dec
Back-light 50%
Cooling fan AUTO
Completion Ring
Beep always
-
Dec
+
Inc
Inc
Dec
-
Dec
+
Inc
Regenerative DSC
OFF 1.0A 4.50V
Delay 0min
-
Dec
+
Inc
Key confirmation and alert tone. If the keyboard sound is ON there will be a
beep when you press any key. If the buzzer is ON the iCharger will
generate an alert tone for certain events.
Key Beep: OFF&ON: (ON, default)
Buzzer: OFF&ON: (ON, default)
Process completion tone. Controls the tones generated at end of charging
or discharging and the cyclic charging/discharging indication.
Options: Beep 5 times, Beep 3 minutes, Beep always (continuous until
user presses STOP), Beep OFF
(Beep always, default)
Back-light and cooling fan control. Adjust the LCD backlight brightness.
There are three cooling fan modes: ON, OFF, AUTO. In AUTO-Mode,
iCharger adjusts the fan automatically to control its internal temperature.
Cooling fan: OFF, ON & AUTO (AUTO, default)
Discharge reduce setting. When you set it to ―ON‖,If the final voltage target
storage voltage is reached, the buzzer will beep for three times, and the left
of the second line display "D>>", and the charger enters into the high
precision discharge process. The process won‘t stop until the current
reaches xx% of the configured discharge current.
Reduce: ON, OFF Range: 1 – 99%
Regenerative discharge setting. In the second line, these items are set:
Regenerative discharge ON/OFF, current limit, voltage limit.
Regenerative discharge: OFF, ON (OFF, default)
Regenerative current limit: 1 – 30A (1A, default)
Regenerative voltage limit: 4.50 – 37.0V (4.50V, default)
Inc
Dec
Discharge reduce
OFF 50%
Delay 0min
-
Dec
+
Inc
-
Dec
+
Inc
Inc
Dec
-
Dec
+
Inc
-
Dec
+
Inc
Inc
Dec
Regenerative DSC: OFF
iCharger
User
Batt.
Pack
Output
+
-
-
+
Power
Supper
Input
Discharge
Current
+
-
+
-
Regenerative DSC: ON
iCharger
User
Batt.
Pack
Output
+
-
-
+
Rechargeable
Power Supper
For example:
Pb battery etc.
Input
Discharge
Current
+
-
+
-
Regenerative discharge OFF