beautypg.com

Resume defaults? confirm (enter), Battery pack ir 45m ω – ProgressiveRC 206B iCharger User Manual

Page 8

background image


-8-

iCharger Synchronous Balance Charger/Discharger 206B

Keyboard basics

1. Go to the main menu, press the Inc button or the Stop/Batt type button to go down, and press the

Dec button to go up: press the Start/Enter button to enter a sub-menu.

2. In a sub-menu, press Start/Enter to blink the chosen item, and then alter the value with Inc or Dec.

With nothing blinking you can go to the sub-menu below with Inc and above with Dec. Press
Stop/Batt type to go back to the previous screen.

3. In some sub-menus, press and hold Start/Enter for more than 3 seconds to start the process, such as

starting charging or discharging.

4. During the charging/discharging process you can terminate the process at any time by pressing

Stop/Batt type and check the attached information with IncorDec. Press Start/Enter to go back to
the main information screen.

5. During the discharge process, press Start/Enter to alter the discharge current. When the discharge

current blinks, press Inc to increase it or Dec to decrease it, then press Start/Enter to confirm the
change.

6. Press Stop/Batt type for more than 3 seconds to start the display of the active test information as per

the following diagram.

Present testing information














7. Reset to Defaults function. Press

Stop/Batt type and Start/En

ter together for more than 3 seconds to

obtain this display:




8. Adjust Current, Temp. Cut-Off, Safety timer, Capacity Cut-Off in course of charging and discharging.


Method of Application:
When in charging and discharging interface, press Start/Enter for 3 seconds, and current begins
blinking.
Press IncorDec to adjust current, and press Start/Enter to save changes. If users press Stop/Batt
type
or without any operation for 1 minute, it will cancel and quit from the changes.

Note: Adjustment of current is only effective for charging and discharging, which will not saved as user
setting.


When in charging and discharging interface, press Dec for several times to see need-to-be changed
information interface. Press Start/Enter for 3 seconds, and the value begins blinking. The adjust method
is as same as the above.

Note: This change can be saved as user setting.

Resume defaults?
CONFIRM (ENTER)

Vi11.94V Int30℃
Vo 8.23V Ext25℃

Output

Volt.

Input

Volt.

Int.

Temp.

Ext.

Temp.

Inc

1:4.11 4.12 ----
4:---- ---- ----

1: 21 24 m

Ω

4: m

Ω

Dec

Battery Pack IR

45m

Ω

Dec

In this display the output voltage is the idle voltage measured at the
output terminals (that is, the voltage of the connected battery pack).

Individual cell voltage from
the balance port.

Per cell resistance from
the balance port.

Stop/Batt type

>3 seconds

Pressing Start for 3 seconds to monitor the resistance again.

Press Start/Enter to reset all values to the system-default settings.

Pack cells resistance from
the balance port.