beautypg.com

Reverse polarity check connection, Connection break down, Short error break down – ProgressiveRC 206B iCharger User Manual

Page 28: Input voltage low voltage, Input voltage over voltage, Balance port cell low vol, Balance port cell high vol, Balance port not connect, Battery check low voltage, Battery check over voltage

background image


-28-

iCharger Synchronous Balance Charger/Discharger 206B

Error messages


















































The output is connected to a battery with incorrect polarity


This will be displayed when an interruption of the connection between
battery and the charger output has been detected during charging or
discharging.


A short-circuit at output. Please check the charging leads.



The input voltage is below the limit set in the USER SET menu.



The input voltage is over the limit (32V).


The voltage of one of the cells in the Lithium battery pack is too low.
Please check the cell voltages one by one.


The voltage of one of the cells in the Lithium battery pack is too high.
Please check the cell voltages one by one.

In Balance charge mode, no battery is connected to the charger‘s balance
port.


Without using the balance port, the cell count detected by the charger is
less than that set by the user.
Please check the cell count of the battery pack.

Without using the balance port, the cell count detected by the charger is
higher than that set by the user.
Please check the cell count of the battery pack.

The internal temperature is over 65℃(149

o

F). Cool down the unit.




The external temperature sensor detects (battery) temperature above the
limit.


The capacity (mAh) charged or discharged reached the configured
protection limit.


The charge or discharge time reached the configured protection limit.

REVERSE POLARITY

CHECK

CONNECTION

CONNECTION
BREAK DOWN

SHORT ERROR
BREAK DOWN

INPUT VOLTAGE

LOW VOLTAGE

INPUT VOLTAGE

OVER VOLTAGE

BALANCE PORT

CELL LOW VOL

BALANCE PORT
CELL HIGH VOL

BALANCE PORT

NOT CONNECT

BATTERY CHECK

LOW VOLTAGE

BATTERY CHECK

OVER VOLTAGE

Int. TEMP OVER

CHG STOPPED

Ext. TEMP OVER

CHG STOPPED

CAPACITY OVER

STOPPED

SAFETY TIME OUT

STOPPED