beautypg.com

4 electrical specifications – Kontron CP3-SVE-P200DC-24V User Manual

Page 8

background image

Page 8

PD14: CP3-SVE-P200DC-24V

CPCI Power Supply

RID 24139 PD14, Rev.02

2.4

Electrical Specifications

INPUT

OUTPUT

REGULATION

PARAMETER

CONDITIONS / DESCRIPTION

MIN

NOM

MAX

UNITS

Input Voltage - DC

Continuous input range.

18

36

VDC

Hold-up Time

From 24 VDC input

None

ms

Input Current

At full rated load

A

Input Protection

Non-user serviceable, internally-located input line fuse.

Inrush Surge Current

Internally limited by thermistor and electronic switch.

20

A

Operating Frequency

Switching frequency of main output transformer.

125

145

kHz

PARAMETER

CONDITIONS/DESCRIPTION

MIN

NOM

MAX

UNITS

Efficiency

Full rated load, 24 VDC input

>= 83

%

Minimum Load; V1,
V2, V3

Minimum load required to maintain regulation with no
load on V4

None

A

Minimum Load, V3

Minimum load on V3 required to maintain regulation on V4 None

A

Ripple and Noise

Full load, 20 MHz bandwidth

See Regulation table

Output Power

250 LFM forced-air cooling (ca. 1.3 m/s)

200

W

Overshoot /
Undershoot

Output voltage overshoot / undershoot at turn-on

0

%

Regulation

Varies by output. Total regulation includes: line changes
over the specified input range, changes in load starting at
50% load and changing to 100% load

See Regulation table

Turn-on Delay

Time required for initial output voltage stabilization

1

sec

Initial Setting Accuracy

±1

%

OUTPUT

VOLTAGE

ADJUSTMENT

RANGE

OUTPUT

CURRENT

LINE

REGULATION

LOAD

REGULATION

RIPPLE & NOISE

pk-pk

V1

+5V

N/A

25A

0.5%

1%

< 60 mV

PP

V2

+3.3V

N/A

36A

0.5%

1%

< 60 mV

PP

V3

+12V

N/A

3A

0.5%

1%

< 120 mV

PP

V4

-12V

N/A

0.5A

0.5%

1%

< 120 mV

PP