beautypg.com

Kontron CP3-SVE-P200DC-24V User Manual

Page 10

background image

Page 10

PD14: CP3-SVE-P200DC-24V

CPCI Power Supply

RID 24139 PD14, Rev.02

ENVIRONMENTAL

Conducted
Disturbance

Per EN61000-4-6, level 2.

3

V

Insulation
Resistance

Input to Output.

tbd

M

Ω

PARAMETER

CONDITIONS/DESCRIPTION

MIN

NOM

MAX

UNITS

Altitude

Operating.
Non-Operating.

ASL Ft.

Operating
Temperature

With 250 LFM forced-air cooling At 100% load:
Derate linearly above 50°C by 5W per °C. At 50%
load:

- 20

+ 55
+ 70

°C

Storage
Temperature

- 40

+ 85

°C

Relative Humidity

Non-Condensing.

5

93

%RH

Shock

Peak acceleration.

20

GPK

Vibration

Random vibration, 10 Hz to 500 Hz, 3 axis.

1.9

GRMS

Warning!

Adequate thermal cooling of the power supply must be ensured.
Therefore do not obstruct or hinder cooling air circulation or heat con-
duction within the power supply or surrounding equipment.
Failure to comply with this warning may result in damage to your
equipment.

SAFTEY, REGULATORY, AND EMI

PARAMETER

CONDITIONS/DESCRIPTION

MIN

NOM

MAX

UNITS