5 environmental specification, 1 temperature specification, 2 humidity – Kontron ETX-CD User Manual
Page 15: Environmental specification, Temperature specification, Humidity

ETX®-CD / Specification
3.5
Environmental Specification
3.5.1
Temperature Specification
General Kontron Specification
Operating
Non-operating
Commercial grade
0°C to +60°C
-30°C to +85°C
Extended Temperature(E1)
-25°C to +75°C
-30°C to +85°C
Industrial grade by Screening (XT)
-40°C to +85°C
-40°C to +85°C
Industrial grade by Design (E2)
-40°C to +85°C
-40°C to +85°C
Please see chapter Product Specification for available variants for extended or industrial
temperate grade
With Kontron heatspreader plate assembly
The operating temperature defines two requirements:
» the maximum ambient temperature with ambient being the air surrounding the module.
» the maximum measurable temperature on any spot on the heatspreader's surface
Without Kontron heatspreader plate assembly
The operating temperature is the maximum measurable temperature on any spot on the module's surface.
3.5.2
Humidity
» 93% relative Humidity at 40°C, non-condensing (according to IEC 60068-2-78)
15