Assembly instructions etxexpress® minibaseboard, 1 assembly instructions etxexpress® minibaseboard – Kontron COMe Ref. Carrier T2 User Manual
Page 62
COM Express™ miniBaseboard Type 2
/ Single Supply Mode
57
7.1 Assembly Instructions ETXexpress® miniBaseboard
Follow the assembly instruction below to enable Single Supply operation:
For correct CPLD supply:
»
Remove R710 (10kOhm; bottom)
»
Mount R705 (100kOhm; bottom)
»
Mount R61 (210kOhm; bottom)
To switch CPLD in single supply mode:
»
Remove R712 (0R; bottom)
»
Mount R711 (1kOhm, bottom)
To enable 5V Standby:
»
Mount R46 (0R; top)
»
Mount R60 (210kOhm; bottom)
To ensure that there is no short with the onboard generated voltages:
»
Remove J58 (top), to ensure, that there is no short with the onboard generated voltages possible.
Optional:
»
Remove R490 (0R, top) and mount on R491 (top) to enable the power save mode
»
FAN1 output is 8.5V -12V. Place R51 (0R; bottom) to fix FAN1 output voltage to 5V
»
FAN2 is not supported. Remove R53 (0R; bottom) and place it on R52 (bottom) to enable FAN2 with +5V
output voltage.