6 environmental specification, 1 temperature specification, 2 humidity – Kontron COMe-bPC2 User Manual
Page 22: Environmental specification, Temperature specification, Humidity
COMe-bPC2 / Product Specification
3.6
Environmental Specification
3.6.1
Temperature Specification
General Specification
Operating
Non-operating
Commercial grade
0°C to +60°C
-30°C to +85°C
Extended (E1)
-25°C to +75°C
-30°C to +85°C
Industrial grade (E2)
-40°C to +85°C
-40°C to +85°C
Standard modules are available for commercial grade temperature range. Please see
chapter Product Specification for available variants for extended or industrial temperate
grade
With Kontron heatspreader plate assembly
The operating temperature defines two requirements:
» the maximum ambient temperature with ambient being the air surrounding the module.
» the maximum measurable temperature on any spot on the heatspreader's surface
Without Kontron heatspreader plate assembly
The operating temperature is the maximum measurable temperature on any spot on the module's surface.
3.6.2
Humidity
» Operating: 10% to 90% (non condensing)
» Non operating: 5% to 95% (non condensing)
22