4 connector x1b row c, Connector x1b row c, Come-bsc2 / pinout list – Kontron COMe-bSC2 User Manual
Page 66
COMe-bSC2 / Pinout List
7.4
Connector X1B Row C
Pin
Signal
Description
Type
Termination
Comment
C1
GND
Power Ground
PWR
-
-
C2
IDE_D7
IDE Data Bus
I/O-5T
-
-
C3
IDE_D6
IDE Data Bus
I/O-5T
-
-
C4
IDE_D3
IDE Data Bus
I/O-5T
-
-
C5
IDE_D15
IDE Data Bus
I/O-5T
-
-
C6
IDE_D8
IDE Data Bus
I/O-5T
-
-
C7
IDE_D9
IDE Data Bus
I/O-5T
-
-
C8
IDE_D2
IDE Data Bus
I/O-5T
-
-
C9
IDE_D13
IDE Data Bus
I/O-5T
-
-
C10
IDE_D1
IDE Data Bus
I/O-5T
-
-
C11
GND
Power Ground
PWR
-
-
C12
IDE_D14
IDE Data Bus
I/O-5T
-
-
C13
IDE_IORDY
IDE I/O Ready
I-5T
PU 4k7 3,3V (S0) -
C14
IDE_IOR#
IDE I/O Read
I/O-3,3
-
-
C15
PCI_PME#
PCI Power Management Event
I/O-3,3
-
int. PU 20k in PCH
C16
PCI_GNT2#
PCI Bus Grant 2
O-3,3
-
-
C17
PCI_REQ2#
PCI Bus Request 2
I-5T
PU 2k7 3,3V (S0) -
C18
PCI_GNT1#
PCI Bus Grant 1
O-3,3
-
-
C19
PCI_REQ1#
PCI Bus Request 1
I-5T
PU 2k7 3,3V (S0) -
C20
PCI_GNT0#
PCI Bus Grant 0
O-3,3
-
-
C21
GND
Power Ground
PWR
-
-
C22
PCI_REQ0#
PCI Bus Reqest 0
I-5T
PU 2k7 3,3V (S0) -
C23
PCI_RST#
PCI Bus Reset
O-3,3
-
-
C24
PCI_AD0
PCI Adress & Data Bus line
I/O-5T
-
-
C25
PCI_AD2
PCI Adress & Data Bus line
I/O-5T
-
-
C26
PCI_AD4
PCI Adress & Data Bus line
I/O-5T
-
-
C27
PCI_AD6
PCI Adress & Data Bus line
I/O-5T
-
-
C28
PCI_AD8
PCI Adress & Data Bus line
I/O-5T
-
-
C29
PCI_AD10
PCI Adress & Data Bus line
I/O-5T
-
-
C30
PCI_AD12
PCI Adress & Data Bus line
I/O-5T
-
-
C31
GND
Power Ground
PWR
-
-
C32
PCI_AD14
PCI Adress & Data Bus line
I/O-5T
-
-
C33
PCI_C/BE1#
PCI Bus Command and Byte enables 1 I/O-5T
-
-
C34
PCI_PERR#
PCI Bus Grant Error
I/O-5T
PU 2k7 3,3V (S0) -
C35
PCI_LOCK#
PCI Bus Lock
I/O-5T
PU 2k7 3,3V (S0) -
C36
PCI_DEVSEL# PCI Bus Device Select
I/O-5T
PU 2k7 3,3V (S0) -
C37
PCI_IRDY#
PCI Bus Bus Initiator Ready
I/O-5T
PU 2k7 3,3V (S0) -
C38
PCI_C/BE2#
PCI Bus Command and Byte enables 2 I/O-5T
-
-
C39
PCI_AD17
PCI Adress & Data Bus line
I/O-5T
-
-
C40
PCI_AD19
PCI Adress & Data Bus line
I/O-5T
-
-
C41
GND
Power Ground
PWR
-
-
C42
PCI_AD21
PCI Adress & Data Bus line
I/O-5T
-
-
C43
PCI_AD23
PCI Adress & Data Bus line
I/O-5T
-
-
C44
PCI_C/BE3#
PCI Bus Command and Byte enables 3 I/O-5T
-
-
C45
PCI_AD25
PCI Adress & Data Bus line
I/O-5T
-
-
C46
PCI_AD27
PCI Adress & Data Bus line
I/O-5T
-
-
C47
PCI_AD29
PCI Adress & Data Bus line
I/O-5T
-
-
C48
PCI_AD31
PCI Adress & Data Bus line
I/O-5T
-
-
C49
PCI_IRQA#
PCI Bus Interrupt Request A
I-5T
PU 2k7 3,3V (S0) -
C50
PCI_IRQB#
PCI Bus Interrupt Request B
I-5T
PU 2k7 3,3V (S0) -
C51
GND
Power Ground
PWR
-
-
C52
PEG_RX0+
PCIexpress Graphics Receive + (0)
DP-I
-
-
C53
PEG_RX0-
PCIexpress Graphics Receive - (0)
DP-I
-
-
C54
TYPE0#
n.c. for type 2 module
nc
-
-
C55
PEG_RX1+
PCIexpress Graphics Receive + (1)
DP-I
-
-
C56
PEG_RX1-
PCIexpress Graphics Receive - (1)
DP-I
-
-
C57
TYPE1#
n.c. for type 2 module
nc
-
-
C58
PEG_RX2+
PCIexpress Graphics Receive + (2)
DP-I
-
-
C59
PEG_RX2-
PCIexpress Graphics Receive - (2)
DP-I
-
-
C60
GND
Power Ground
PWR
-
-
C61
PEG_RX3+
PCIexpress Graphics Receive + (3)
DP-I
-
-
C62
PEG_RX3-
PCIexpress Graphics Receive - (3)
DP-I
-
-
C63
RSVD
n.c.
nc
-
-
C64
RSVD
n.c.
nc
-
-
66