5 atx mode, 6 single supply mode, Atx mode – Kontron COMe-bHL6 User Manual
Page 24: Single supply mode, Come-bhl6 / product specification
COMe-bHL6 / Product Specification
3.5.5
ATX Mode
By connecting an ATX power supply with VCC and 5VSB, PWR_OK is set to low level and VCC is off. Press the Power Button to
enable the ATX PSU setting PWR_OK to high level and powering on VCC. The ATX PSU is controlled by the PS_ON# signal
which is generated by SUS_S3# via inversion. VCC can be 8.5V - 20V in ATX Mode. On Computer-on-Modules supporting a
wide range input down to 4.75V the input voltage shall always be higher than 5V Standby (VCC > 5VSB).
State
PWRBTN#
PWR_OK
V5_StdBy
PS_ON#
VCC
G3
x
x
0V
x
0V
S5
high
low
5V
high
0V
S5 S0
→
PWRBTN Event
low high
→
5V
high low
→
0 V VCC
→
S0
high
high
5V
low
VCC
3.5.6
Single Supply Mode
In single supply mode (or automatic power on after power loss) without 5V Standby the module will start automatically
when VCC power is connected and Power Good input is open or at high level (internal PU to 3.3V). PS_ON# is not used in
this mode and VCC can be 8.5V - 20V.
To power on the module from S5 state press the power button or reconnect VCC. Suspend/Standby States are not
supported in Single Supply Mode.
State
PWRBTN#
PWR_OK
V5_StdBy
VCC
G3
x
x
x
0
G3 S0
→
high
open / high
x
connecting VCC
S5
high
open / high
x
VCC
S5 S0
→
PWRBTN Event
open / high
x
reconnecting VCC
Signals marked with “x” are not important for the specific power state. There is no
difference if connected or open.
All ground pins have to be tied to the ground plane of the carrier board.
24