beautypg.com

Kontron MSM800BEV V101 BIOS User Manual

Page 41

background image

Geode LX800 / LX900

/ BIOS

www.kontron.com

39

Video and Flat Panel Configuration

The following menu allows configuration of the video settings for the system. To change an option, select the field
using the arrow keys (↑↓) and then hit to change the value of the field. The menu system will also display the
bond-out option for either a flat panel or a CRT.

Video Memory: Allows selection of the amount of video memory to reserve on the system. The options are or

4MB to 16 MB.

Multi-monitor Configuration: Allows the selection of the mode for the video controller when an external monitor is

present; choices include Disabled, Primary and Secondary.

Flat Panel Configuration: Allows the auto or manual configuration of the flat panel.

Type: Enables selection of the type of flat panel; choices are Auto Detect, TFT, LVDS. Auto Detect is typically

recommended. (If Auto Detect is selected, the Resolution, Bus Width and Data type will be grayed
out.)

Resolution: Allows the setting of the resolution of the panel. The choices are 640x480, 800x600, 1024x768,

1152x864, 1280x1024. (Only active if Auto Detect is not selected.)

Bus Width: Allows the selection of the bus width for the panel. The options are 8, 9, 12, 16, 18, or 24bits.

(Only active if Auto Detect is not selected.)

Data Type: Allows selection of the data type for the panel; options are Normal or 2x. (Only active if Auto

Detect is not selected.)

Refresh Rate: Allows selection of the monitor’s refresh rate. The options are 60, 70, 72, 75, or 85Hz.
HSYNC Polarity: Selects the active polarity of the HSYNC signal to the panel; options are Active Low or Active

High.

VSYNC Polarity: Selects the active polarity of the VSYNC signal to the panel. The options are Active Low or

Active High.

LP Active Period: Selects the active period of the LDE/MOD (LP) signal; options are Free Running or Active

Only.

SHFCLK Active Period: Selects the active period of the SHFCHK signal; options are Free Running or Active

Only.

Backlight Configuration: Allows configuration of the backlight.

Backlight Enable: Allows the backlight to be Enabled or Disabled.
Initial Brightness: Selects the initial brightness of the panel. Options are Last Value, 0% (off),

10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%, 90%, 100% (full on).

This manual is related to the following products: