Fru information, 1 fru version identification, 2 fru data update – Kontron AM4022 IPMI Firmware User Manual
Page 39: 1 fru version identification 6.2 fru data update, Am4022 ipmi firmware
AM4022
IPMI Firmware
ID 1052-3624, Rev. 1.0
Page 39
The next step is the activation of the newly downloaded MMC firmware. This is done using
Detailed information about the currently active firmware versions and the redundant copies
can be obtained using the following command:
Some information about the MMC’s upgrade capabilities can be determined using the com-
mand:
To perform a manual rollback to the previously good firmware image, use the following
command:
6.
FRU Information
The MMC provides 4 kB of non-volatile storage space for FRU information. Some of the data
stored there, such as the Module Current Requirements record or E-Keying information (refer
to AMC.0 specification for details), are mandatory for module functionality in an ATCA/AMC en-
vironment.
Please note that missing FRU information possibly will prevent the AMC module from being ac-
cepted by the carrier controller during the hot swap process, and the module will possibly not
receive payload power.
Full low-level access to read or write a module's FRU information is provided by regular IPMI
FRU Device commands. Please be careful when writing FRU information directly using stan-
dard IPMI commands. Damaging the FRU information may lead to a non-working payload.
6.1
FRU Version Identification
The FRU data fields, as defined in the IPMI specification 2.0, are used to record the version of
the FRU installed. The revision number is incremented for each new release of FRU data.
Example of board FRU ID: “STD_R01”
Example of product FRU ID: “STD_R01”
6.2
FRU Data Update
Update of the FRU data can be done via regular IPMI FRU device commands. The correct FRU
data must be prepared at the factory.
ipmitool fwum upgrade
ipmitool fwum status
ipmitool fwum info
ipmitool fwum rollback