Am4022 uefi bios the uefi shell – Kontron AM4022 uEFI BIOS User Manual
Page 63
AM4022 uEFI BIOS
The uEFI Shell
ID 1052-1333, Rev. 1.0
Page 57
OPTIONS:
The listing below provides an overview of the possible options and a
short description of their functionality.
To view all of the possible parameters for a given option, use the
command “kipmi -?
DESCRIPTION
fru
Used to display FRU data for the specified fru device
Numeric FRU device ID. The FRU ID 0 is used
by default if no FRU ID is entered.
info
Used to display IPMI firmware information
ipmb
Displays IPMB bus settings
The redundant mode is not available on the
AM4022. Please leave this function at single
mode.
irq
Used to display or set the IRQ number of the KCS
interface
The board must be reset for the settings to be
applied.
mode
Used to display or set the IPMI controller (MMC)
operating mode
The BMC mode is not available on the
AM4022. If the parameter “bmc” is used, it is
ignored.
net
Used to set IPMI-over-LAN (IOL) or Serial-over-LAN
(SOL) parameters
sel
Display the system event log
The AM4022 does not have a system event log.
sensor
Used to display all available board sensors or
display a specific sensor’s data
raw
Used to issue a raw IPMI command from the uEFI
shell to the onboard IPMI controller (MMC)
rawsendmessage
Used to issue a raw IPMI command from the uEFI
shell to another device on the IPMB-L bus
This command makes it possible for the
AM4022 to communicate with other devices in
the system using the IPMB-L bus.
info
Used to display IPMI firmware information
kipmi (continued)