820153 DC-DC Supply 10-25Vin 150W
KTD-00696-D
Public User Manual
Date: 2008-04-24 Page
3 of 9
The power supply can be operated in two types of modes: “Standard ATX Supply Mode” and “Battery Driven
Application Mode”. The input power voltage shall be 10 – 25V except for Battery Driven Application Mode
where the minimum power input voltage is 11.2V (down to 8V is allowed for maximum 1 minute). The power
input is protected against over-voltage transients, short circuits (>15A) and in Battery Driven Application Mode
the battery is protected against Deep Discharging.
In order to estimate if the DC-DC Power Supply is suitable for a specific project the following table can be
used.
The allowed load (without forced air) can be compared to the maximum load of the actual board. Maximum
load from LCD, HDD, PCI, AGP cards must be taken into consideration to make sure none of the outputs is
overloaded. The “green” numbers are the available power for these loads.
Mechanical Drawing
Voltage Output
Max load / [A]
(fan less)
Peak Load / [A]
(< 60 sec.)
5V 6
12
5VSB 1,5
2
3.3V 6
12
-12V 0,11
0.2
12V 5,25
9
Loads in Ampere
KT690mITX 786LCD/mITX 886LCD-M
986LCD-M
Voltage Output
Turion
1.6G
Sempron
1.00G
733/133 400/100
1600/400 800/400 Duo
2GHz Celeron
1.06G
5V 3,2
2,3
2,4
3,1
1,7
4,3
1
5
4,7
1,3
3
3
2,5
3,5
2,1
3,9
5VSB 0,3
1,2
0,3
1,2
0,3
1,2
0,3
1,2
1,2
0,3
1,2
0,3
0,7
0,8
0,2
1,3
3.3V 1,3
2,6
1,3
2,6
3,2
2,8
2,5
3,5
2,6
3,4
2,6
3,4
1,3
4,7
1,6
4,4
-12V -
0,1
-
0,1
-
0,1
-
0,1
-
0,1
-
0,1
0,05
0,06
-
0,1
12V 2,4
0,9
0,8
2,5
0,4
4,8
0,3
4,9
0,6
4,6
0,6
4,6
2,7
2,5
0,6
4,6
160.0
153.0
7.0
45.0
27.0
Measures in mm.