4 compliance – Kontron RTM806x User Manual
Page 16
3
www.kontron.com
* Designed to meet or exceed
1.4
Compliance
This product conforms to the following specifications:
• USB 2.0 - Universal Serial Bus Version 2.0
• PICMG3.0 R3.0 - Advanced Telecommunication Computing Architecture (see note below)
• PICMG HPM.1
• SAS1R10 - Serial Attached SCSI - 1.0 Revision 10.
• SFF-
8088
(T10 Technical Committee and SCSI Trade Association)
• IEEE 802.3z (fiber interface)
• IPMI v2.0
• AMC.0 R2.0
Environmental
Temperature*
Operating: 0-55°C/32-131°F with 3.8 CFM airflow
Storage and Transit: -40 to +70°C/-40 to 158°F
Environmental
Humidity*
Operating: 15% to 90% @55°C/131°F non-condensing
Storage and Transit: 5% to 95% @ 40°C/104°F non-condensing
Environmental Altitude*
Operating: 4,000 m / 13,123 ft
Storage and Transit: 15,000 m / 49,212 ft
Environmental Shock*
Operating: 3G, half-sine 11ms, each axis
Storage and Transit: 18G, half-sine 11ms, each axis
Environmental
Vibration*
Operating: 5-200Hz. 0.2G, each axis
Storage and Transit: 5 Hz to 20 Hz @ 1 m2/s3 (0.01 g2 /Hz) (flat) 20 Hz to 200 Hz @ -3 dB/oct (slope
down)
Reliability
•
Whole board protected by an active breaker
•
USB voltage protected by an active breaker
Safety / EMC
•
Safety: CE Mark to EN 60950-1:2001. Meets or exceeds UL 60950-1/CSA C22.2 No 60950-1-07.
•
Designed to meet GR-1089-CORE
•
EMI/EMC: FCC 47 CFR Part 15, Class A; CE Mark to EN55022/EN55024/EN300386
Warranty
Two years limited warranty
Note:
Board might not be 100% compliant to ATCA PICMG 3.0 Specification REQ 4.94 when a hard drive is
present on the RTMHDD. The HDD might connect the Logic Ground and the Shelf Ground. By default
the Logic Ground and the Shelf Ground are connected through a removable screw.
Features