TRANSMISSION
PROGRAM
PARKING
LIGHTS
SWITCH
ECU
LED
(-) UNLOCK OUTPUT
+12 V FOR RELAYS
(-) LOCK OUTPUT
ENGINE
ECU
GREEN
BLUE
RED
FUEL
PUMP
PINK
RED
BROWN
GRAY
RED
WHITE
+10A or (-) 0.5A OUTPUT
IGN
RED/WHITE
TACH INPUT
ORANGE/BLACK:
(-)HOOD SWITCH
GRAY
(+12V) BRAKE PEDAL RESET
BLACK
PURPLE
BROWN
ORANGE:
YELLOW/BLACK
(-) GLOW PLUG INPUT
PINK
NOTE: USE EXTERNAL RELAYS FOR HIGH-CURRENT
YELLOW/WHITE
(-)OEM REARM
(-) START ACTIVATION
GREEN
(-) HORN CHIRP / HONK
(-)OEM DISARM
(GREATER THAN 30A) IGNITION CIRCUITS.
ACC
GROUND
(-) AUX. (TRUNK POP)
or DOME LIGHT
FUSE
FUSE
30A
TACH
30A
1
2
0
3
4 5
or ANTI-GRIND
6
(-) IGNITION
RELAY OUTPUT
7
8
+
BATTERY
DIESEL WAIT
TO START LAMP
(-) NEGATIVE ENGINE
STARTER
START / STOP or
WAIT
-
JUMPER
PINK/WHITE
LIGHT
(OPTIONAL)
FACTORY
HORN
STARTER
IGN #2 or
ACC #2 or
STR #2
JUMPER
SELECT
+/- PARKING
(Only if necessary)
FUSE
10A
TURBO TIMER INPUT
(See page 25
A/C - HEAT
CONTROL
VEHICLE
EZ-30-34DP II
EZ-64TW1 II
EZ-74TW2 II
EZ-84FM II
RECEIVER/ANTENNA PLUG
DATA PORT PLUG
3 PIN
4 PIN
EXPANSION PLUG