Gastroback 46008 Design Vakuum Sealer Plus User Manual
Page 16

38
If you use the container (art.-no.: 46111), plug the other end of
the vacuum hose into the center hole of the rotary switch on the
lid of the container (picture P). Make sure that the switch is
turned to the position »SEAL«. You can choose between: »DRY«,
»MOIST«, »SOFT«, »DELICATE«. If you make no selection, the
setting of »DRY« is automatically selected - the indicator light
illuminates green. Press the »CANISTER SWITCH« button (pic-
ture m) on the right side of the appliance. The vacuum pump
starts to operate audibly. Press for a few seconds at the start of
the vacuum process easily on the container lid or on the hose
adapter to ensure that no air escapes from a gap or the hose is
loose. When the maximum vacuum has been reached, the pro-
cess will be terminated automatically. The foods are now vacuum
packed in the container.
note: To test the vacuum, you can try to move the lid - it should
not move.
5.
On canisters 46111 you have the option to label the date of
vakuuming on the lid of the containers (picture Q).
6.
Remove the vacuum hose from the container. If you wish to
vacuum seal another container, wait approximately 2 minutes to
let the appliance cool down. Thereafter, repeat the process.
7.
When you have finished vacuum sealing in containers, just
pull the small adapter of the vacuum hose upwards to remove it from the vacuum port.
manual vacuum
If you want to vacuum step by step and seal at a later time, press the »MANUAL VACUUM«
button (picture r). You can determine your self how much is to be vacuumed - eg for sen-
sitive foods. Press and hold the button - the indicator light illuminates green - the appliance
is vacuuming. Release the button, the appliance will stop immediately vacuuming up and
the indicator light turnes off. You can then seal the vacuum bag manually.
manual seal
If you do not want to vacuum, and seal only, eg for the production of a vakuumiing bags or
for additional welds on a bag press the »MANUAL SEAL« button. The indicator light for the
sealing function illuminates blue. Once the seal is completed, the light turns off.
Picture Q
Picture R
Picture P