beautypg.com

Introduction – ETS-Lindgren HI-2602 Interlock Monitor User Manual

Page 7

background image

Introduction

| 7

Introduction

The HI-2602 Interlock Monitor provides continuous surveillance of microwave

fields for protection of personnel and equipment. The instrument accepts an input

from a single, remotely mounted sensing probe using ETS-Lindgren’s patented

microwave field sensor. Useable in any critical area, the HI-2602 interlocks with

any microwave source or alarm.

The HI-2602 may be set to trigger at any RF level up to 2.0 mW/cm². When the

RF level sensed by the probe exceeds a preset RF level, the RF Fail indicator

will light and the output interlock will latch

The instrument is calibrated for measurement in the 2450 MHz ISM band only

and is intended for area hazard monitoring. It is not intended for RF leakage

compliance measurements.

The HI-2602 Interlock Monitor is designed to operate from standard 50/60 Hz

120 or 240 VAC power. The AC input power, is customer specified and set at the

factory.