Pre-Installation Tasks

|

23

4.0 Pre-Installation Tasks

Before installing any components, follow the

safety information in the ETS-Lindgren

Product Information Bulletin included with your

shipment.

Prior to installing the Model 4340 Digital Camera System (CCTV), complete

these pre-installation tasks.

If you are installing one of the optional configurations listed under

Optional Configurations and Additional Components on page 10,

additional pre-installation tasks may be required. For a description of

pre-installation tasks for optional configurations, see Install Optional

Components on page 33.

Demonstrate Good Shielding Practices

Certain guidelines must be followed to retain the RF shielding integrity of the

chamber. These good shielding practices consist of the following:

Doors must be periodically cleaned and lubricated.

Screw-retaining items mounted within the enclosure must not

penetrate through both shields of a modular panel system. Screws

must not penetrate the screen system of a Series 60 at all.

Framing screws must never be used to fasten items within the

enclosure.

When a hole is bored for a new penetration, all burrs must be removed

and both the perimeter of the hole and the penetration must be

cleaned with a cleaning agent before installing the new penetration.

Nothing must penetrate the enclosure wall, floor, or ceiling without use

of a proper electromagnetic-designated penetration.