beautypg.com

EFCO S5600 Concealed Vent User Manual

Page 13

background image

EFCO CORPORATION 6/2012 PART NO. Y310

Page 13 of 13

Series 5600 Curtain Wall Concealed Vent Installation Instructions

Section IX: Reglaze Instructions

Reglaze Instruction

1.)

Remove Limit device and anti-lift clips.

2.)

Remove sash from opening.

3.)

Remove damaged or broken glass from sash.

4.)

Remove old silicone sealant.

5.)

Remove old setting blocks, jamb blocks, and glazing tape.

6.)

Clean all metal and infill that will contact silicone with proper cleaner, and

then apply primer, if required, as recommended by sealant manufacturer.

7.)

Install setting blocks, jamb blocks, etc. to original position.

8.)

Position infill in the sash frame.

9.)

Apply structural seal to jamb of sash with DOW CORNING #795 Silicone

sealant. Apply cap bead at head, sill, and exterior side of jamb with DOW
CORNING #795 Silicone sealant. Allow a (5) to (7) day curing period after

the unit is reglazed. DO NOT install sash into opening until sealant has
properly cured.

10.)

Reverse steps #5 and #6 as shown above for reinstallation of sash limit

device.

Note: Insulated glass not manufactured by EFCO CORPORATION

must be sent to DOW CORNING for compatibility testing!