12.1 ENVIRONMENTAL SPECIFICATIONS


Rugged
Class

Grade

Operating
Temp.

Storage
Temp

Vibration Shock

Humidity

Other

Specs

C1

Commercial

0ºC to +65ºC
200 linear
ft/minute air
flow

-50C to
+100C

N/A


N/A

Operating: Up
to 90% Non-
Condensing

Conformal
coated: No

Altitude:
33,000 ft.

R1

Rugged,
Forced Air

-20ºC to +75ºC
350 linear
ft/minute air
flow

-50C to
+100C

5Hz-2000Hz
at 2g,
0.38mm
peak
displacement
(operating)

5Hz-2000Hz
at 5g,
0.76mm
peak
displacement
(non-
operating

Per MIL-
STD-810E

20g, 11ms, ½
sine
(operating);

30g, 11ms, ½
sine (non-
operating)


Per MIL-STD-
810E

Operating: Up
to 95% Non-
Condensing

Conformal
coated: Yes

Altitude:
50,000 ft.

R2

Rugged,
Forced Air


-40ºC to +85ºC
450 linear
ft/minute air
flow

-50C to
+100C

5Hz-2000Hz
at 2g,
0.38mm
peak
displacement
(operating)

5Hz-2000Hz
at 5g,
0.76mm
peak
displacement
(non-
operating

Per MIL-
STD-810E

30g, 11ms, ½
sine
(operating);

40g, 11ms, ½
sine (non-
operating)

Per MIL-STD-
810E

Operating: Up
to 95% Non-
Condensing

Conformal
coated: Yes

Altitude:
50,000 ft.