Troubleshooting, Warning, Narrowstik version – Code 3 WingMan for Crown Victoria User Manual
Page 9

9
W ARNING!
PROBLEM
LED module not
operating when
powered.
POSSIBLE CAUSE
a. Bad power/ground
connection.
b. Defective module.
SOLUTION
a. Fix connection.
b. Replace module
TROUBLESHOOTING GUIDE
Troubleshooting
All WingMan Rear Bars are thoroughly tested prior to shipment. However, should you encounter a problem
during installation or during the life of the product, follow the guide below for information on repair and
troubleshooting. Additional information may be obtained from the factory technical help line at 314-426-2700
ext. 2131.
Note: LED modules must be replaced as a module. There are no user
serviceable parts.
QUESTIONS
N/A
This Product contains high intensity LED devices. To prevent eye damage,
DO NOT stare into light beam at close range.
!
WARNING!
Minimum fuse size calculation:
For LED 12 volt electrical current
1.5 x (number of modules being fused)
Example:
2 intersection modules and 6 directional modules.
Minimum fuse requirement for single fuse - 1.5 (8) = 12 A
Product Features
LED lighthead options: Red, Blue, Amber; Directional or Spreading; Flashing or Steady Burn Control
LED lighthead types: LED-X, Optix, LCLED
Size: 36.75" long x 2.00" tall x 7.12" deep
Weight: 7.5 lb
LED Fusing Considerations
Although the average current draw per module is very low, due to the type of circuit used to power each
module, the instantaneous peak current to a module can be significantly higher during low voltage
conditions. To avoid prematurely blowing ATO style fuses or tripping breakers it is recommended the
following rule-of-thumb be used to size fuses or breakers. This is especially important in light bars with
many LED modules running off a single fused source,
NarrowStik Version
The WingMan can be factory configured as a traffic director and operated using an NarrowStik Control
Head. Please refer to the NarrowStik Control Head Manual packaged with the control head for
installation, wiring connections, and operation of the Control Head.
Wiring
Refer to the Narrowstik wiring on page 10 for wire designations. For models with independently flashing
red/blue heads located on each end, the Blue and Brown wires will be used to control these heads. The
Blue wire is connected to+12V and the Brown to Ground. Refer to the Control Head manual for operation
with the Control Head.