beautypg.com

Steady burn setting – Code 3 Triumph User Manual

Page 7

background image

Steady burn Setting

The TRIUMPH's™ Steady Burn feature allows up to two (2) of the light bar's SIRIS™ light heads to be designated to operate in Steady Burn mode.

The Steady Burn SIRIS light heads are always connected to connectors P9 & P10.

The Steady Burn outputs are enabled by the 3-Level control inputs. The TRIUMPH may be configured so that Steady Burn SIRIS light heads are on

when either L1, L2 or L3 are active (JP1 position); when L2 or L3 are active (JP2 position) or just when L3 is active (JP3 position). Simply move the

jumper to the appropriate location (JP1, JP2 or JP3). Refer to the detail in Figure 1.

FLASH PATTERN SELECTION NOTES:

When the ArrowStik® Left and ArrowStik Right wires are both connected to +power, the Center-Out ArrowStik function is activated.

When the Pattern Select wire is connected to +power and all other inputs are off, test mode is enabled to exercise all outputs in

sequence until +power is removed from the wire.

The Steady Burn function for both the Take Down and Alley lights will always override the Wig/Wag Flash function.