Troubleshooting
All SuperVisorTLs are thoroughly tested prior to shipment. However, should you encounter a problem during installation or during the
life of the product, follow the guide below for information on repair and troubleshooting. Additional information may be obtained from
the factory technical help line at 314-996-2800.
Follow the guide below for information on repair and troubleshooting.
TROUBLESHOOTINg gUIDE
Note: LED modules must be replaced as a module. There are no user serviceable parts.
PROBLEM
LED module not
operating when
powered.
QUESTIONS
POSSIBLE CAUSE
a. Bad power/ground
connection.
b. Defective module.
SOLUTION
a. Fix connection.
b. Replace module
N/A
Directional module Flash Pattern - Table 2
CycleFlash (DEFAULT)
Quad Pop Flash75
NFPA QuadFlash75
Triple Pop Flash75
Steadyburn
SingleFlash375
ModelFlash
SingleFlash250
ActiveFlash
SingleFlash150
FiveFlash70
FiveFlash150
QuadFlash70
QuadFlash150
TripleFlash70
DoubleFlash150
DoubleFlash70
TripleFlash150
SingleFlash75
Flash Pattern Header for OPTIX
J1
Momentarily short and release
to change patterns
PCB
Changing Flash Patterns
To change the flash patterns on the LED Light Heads, remove the mounting screws that attach the SuperVisor's Cover to the Outer
Panel to gain access to the printed circuit boards inside (see the exploded view on page 7). Momentarily short and release the pat-
tern change prongs as shown below to change patterns.
Carefully replace the SuperVisor's Cover over the Outer Panel and replace
the Cover Mounting Screws.
Note: Be extremely careful to replace the wiring such that you don't pinch a wire when you replace the Super-
Visor's Cover. Test the unit to be sure that it works properly.