Steady burn option, Warning! tricore® light head flash pattern, Tricore take down flash pattern – Code 3 SuperVisor with TriCore for Dodge Charger User Manual
Page 6
6
Flash Patterns
STANDARD LIgHT HEAD FLASH PATTERNS
PATTERN NO PATTERN DESCRIPTION
1
FAST ALTERNATING QUAD FLASH 100ms/25ms
2
PICKET FENCE SINGLE FLASH 200ms/25ms
3
ALTERNATING SINGLE FLASH 200ms/25ms
4
PICKET FENCE QUAD FLASH 100ms/25ms
5
PICKET FENCE SIX FLASH 75ms/25ms
6
SLOW ALTERNATING QUAD FLASH 150ms/50ms
7
SLOW ALTERNATING SIX FLASH 125ms/25ms
8
FAST ALTERNATING SIX FLASH 75ms/25ms
9
VARIABLE RATE PICKET FENCE, SINGLE FLASH
10
ALTERNATING QUAD FLASH, 80 FPM, NFPA COMPLIANT
11
CYCLE FLASH
12
SIMULTANEOUS QUAD FLASH, 75 FPM, NFPA COMPLIANT
TAKE DOwN FLASH PATTERNS
PATTERN NUMBER
PATTERN DESCRIPTION
1
FAST QUAD 80FPM
2
SLOW QUAD 60FPM
3
FAST SINGLE 375FPM
4 FACTORY DEFAULT
MEDIUM SINGLE 115FPM
5
SLOW SINGLE 60FPM
6
FAST DOUBLE 115FPM
7
SLOW DOUBLE 60FPM
8
FAST SIX 80FPM
9
SLOW SIX 60FPM
10
VARIABLE RATE SINGLE
11
NFPA QUAD 75FPM
12
CYCLE FLASH
This Product contains high intensity TriCore® devices. To prevent eye
damage, DO NOT stare into light beam at close range.
wARNINg!
TriCore® Light Head Flash Pattern
To change the flash patterns of the TriCore Light Heads, activate the Light Bar in Level 1 and then momentarily touch the Green
(Pattern Select) wire to +power. Repeating this procedure allows the operator to cycle through the numerous flash patterns
offered until the desired pattern is achieved.
To reset the flash patterns to the factory default, activate the Light Bar in Level 1 and then hold the Green (Pattern Select) wire
to +power for approximately 4 seconds.
Steady Burn Option
The SuperVisor® can operate Light Head #2 (second Light Head from the driver side) in steady burn mode. To change the #2 Light
Head from flashing to steady burn, remove the mounting screws that attach the SuperVisor's Cover to the Outer Panel to gain
access to the printed circuit board inside (see the exploded view on page 7). Move the Shunt Option Jumper on the printed circuit
board to the "OPTION JP1" position as shown below. The #2 Light Head should now operate in steady burn. Carefully replace the
SuperVisor's Cover over the Outer Panel and replace the Cover Mounting Screws.
Note: Be extremely careful to replace the wiring such that you don't pinch a wire when you
replace the SuperVisor's Cover. Test the unit to be sure that it works properly.
<---------------"OPTION JP1" Jumper Position
TriCore Take Down Flash Pattern
Selecting Flash Patterns:
The Take Down Lights can be programmed to flash at different rates.
STEP 1:
Power-up the light bar. Select the Take Down Flash Mode (ORANGE) by applying +power. Programming will not work if
more than one function is selected at a time.
STEP 2:
Observe the flash pattern and determine which pattern is in operation (see Take Down Flash Patterns). This table shows
the available flash patterns. Once the flash pattern has been determined, proceed to Step 3. NOTE: The default flash pattern for
Take Down Lights is Medium Single 115FPM.
STEP 3:
Scroll to the next pattern by momentarily holding the GREEN wire to +power for ~one (1) second. The light bar will stop
flashing when the wire is connected to +power. Release the wire and the next pattern as listed in Table 5 will begin to flash. The new
pattern is automatically stored each time.