Troubleshooting
All SuperVisor TLs are thoroughly tested prior to shipment. However, should you encounter a problem during installation or during the
life of the product, follow the guide below for information on repair and troubleshooting. Additional information may be obtained from the
factory technical help line at 314-996-2800.
Follow the guide below for information on repair and troubleshooting.
TROUBLESHOOTING GUIDE
Note: LED modules must be replaced as a module. There are no user serviceable parts.
PROBLEM
LED module not
operating when
powered.
QUESTIONS
POSSIBLE CAUSE
a. Bad power/ground
connection.
b. Defective module.
SOLUTION
a. Fix connection.
b. Replace module
N/A
Directional Module Flash Pattern
Flash Pattern
Description
Cycle Flash
Cycles through various patterns @ 70 fpm
Steady-Burn
Steady-Burn
Five Flash
Five Pulses per flash @ 70 fpm
Quad Flash
Four Pulses per flash @ 70 fpm
Triple Flash
Three Pulses per flash @ 70 fpm
Double Flash
Two Pulses per flash @ 70 fpm
Fast Double Flash
Two Pulses per flash @ 85 fpm
NFPA
Four Pulses, 70% Duty Cycle @ 75 fpm
Quad Pop Flash
Four Pulses per flash ( 3 equal, 1 extended) @ 70 fpm
Triple Pop Flash
Three Pulses per flash ( 2 equal, 1 extended) @ 70 fpm
Flash Pattern Header for OPTIX/LED X
J1
PCB
Momentarily short and release
to change patterns